An ice maker that fills but will not eject is common on the KTRS20MHBL, and it is worth fixing before the whole bin freezes solid. Defrost problems are the other frequent cause of trouble, usually a failed heater, thermostat, or timer that lets frost build up until the cabinet starts warming.
KitchenAid KTRS20MHBT
Sagging doors from worn hinge cams are common on the KTRS20MHBT, keeping the seal from meeting the cabinet squarely even with an otherwise good gasket. Condenser coils choked with dust are the other frequent issue, and cleaning them is often enough to bring the compressor’s runtime back to normal.
KitchenAid KTRS20MHWH
A control board that has aged out of service is the part most worth checking on a KTRS20MHWH that no longer follows its own settings. Restricted condenser airflow is the other common cause of gradually worsening cooling, usually solved with a thorough coil cleaning.
KitchenAid KTRS21KLSS
A weeping inlet valve is worth ruling out on a KTRS21KLSS with water behind the cabinet, since the leak can go unnoticed for weeks before it is traced back. Cold control or thermistor drift is the other common issue, leaving the cabinet either running warm or over-freezing the top shelf.
KitchenAid KTRC22EKSS
Loss of refrigerant charge is the issue that most affects whether a KTRC22EKSS is worth repairing, since it can be a significant job depending on where the leak is. Ice maker fill or harvest problems are a separate, less costly issue where an ice maker is fitted.
KitchenAid KTRP21KLWH
Start relay failure is a common cause of a compressor that won’t start on the KTRP21KLWH, even when the compressor itself is fine. A failing evaporator fan is the other issue to listen for, usually starting as a whine before turning into a rattle.
KitchenAid KTRC22EKWH
A condenser fan that has seized or slowed is a common cause of poor cooling on the KTRC22EKWH, especially noticeable in warm weather. Sealed-system problems are the more serious possibility if the fan checks out fine, and if found we say so plainly.
KitchenAid KTRP22EKBT
A door gasket that has hardened with age is common on the KTRP22EKBT, letting warm air in once it stops pulling the door tight. Water supply problems are the other issue to check on a plumbed unit, whether at the valve, the line, or the filter housing.
KitchenAid KTRC22ELBL
Compressor start relay and overload problems are common on the KTRC22ELBL, often heard as a repeated click with no cooling ever starting. Evaporator fan bearing wear is the other issue to watch for, since it can progress until the fan will not start from cold.
KitchenAid KTRC22ELSS
A door seal gone stiff is common on the KTRC22ELSS, letting warm air track in along one edge even when the rest of the door looks properly sealed. Water inlet valve or supply line leaks are the other issue to check on a plumbed unit.