Compressor start relay and overload problems are common on the KUDF204EPA, often heard as a click every few minutes with no cooling following it. Water supply problems are the other issue to check on a plumbed unit, whether at the valve, the line, or the filter housing.
KitchenAid KURR114KSB
Lighting and door-switch problems are worth ruling out on the KURR114KSB before assuming anything is wrong with the cooling system, since a failed switch can affect more than the interior light. An ice maker that fills without ejecting is the other issue reported on this model, usually traced to the ejector mechanism rather than the […]
KitchenAid KUDF204ESB
A door seal gone stiff is common on the KUDF204ESB, letting warm room air track in along one edge. Water inlet valve or supply line leaks are the other issue to check on a plumbed unit, since either can let water appear where it shouldn’t.
KitchenAid KURR204ESB
Sealed-system problems are the one issue worth weighing carefully on a KURR204ESB, since a refrigerant leak or restriction can be a significant repair relative to the cabinet’s value. Sagging doors from worn hinge cams are a far more common and inexpensive fix, and are worth ruling out first if the cabinet seems to be losing […]
KitchenAid KUDR204EPA
Ice production tailing off is common on the KUDR204EPA, usually the fill valve, a frozen fill tube, or the module itself. It is also worth keeping an eye on the crisper runners and door bin lugs, which tend to crack with age and are best replaced while parts can still be found.
KitchenAid KURR304ESS
Handle, hinge, and door-closer wear from years of daily use is common on the KURR304ESS and mostly a cosmetic annoyance. Evaporator fan motor noise is the more meaningful issue — once the fan stops, the fresh food side can climb in temperature while the freezer itself stays cold.
KitchenAid KUDR204ESB
A blocked defrost drain is a common issue on the KUDR204ESB, leaving water under the crispers or running onto the floor until cleared. Handle, hinge, and door-closer wear is the other thing to expect after years of daily use, mostly cosmetic.
KitchenAid KURS24LSBS
Start relay failure is a common cause of a compressor that won’t start on the KURS24LSBS, even when the compressor itself is fine. A weeping inlet valve is the other issue worth checking, since the leak is slow enough to sit behind the cabinet unnoticed for some time.
KitchenAid KTRP22EMSS
The KTRP22EMSS has two failure points that come up again and again. Control board problems are the first — after years of service the board can stop tracking the settings altogether — and start relay failure is the second, since it can leave a mechanically sound compressor unable to start at all.
KitchenAid KTRS22ELWH
Ice maker fill or harvest problems are worth checking on a KTRS22ELWH fitted with one that is producing less ice than usual. An interior lamp that has failed, or a door switch that no longer tells the control the door is closed, is the other common complaint.